Pile Group Analysis
When several piles share one rigid cap, they no longer behave like the same number of single piles. Vertically, the group may carry less than the sum of its piles, and the piles and the soil between them may fail together as one block. Laterally, the cap forces every pile to the same head deflection, but the rows do not share the load equally: the leading row pushes into undisturbed ground, while the rows behind it stand in its shadow. This macro answers both questions for one array of identical piles.
The example on this page is pile cap PC4 under column C4 of a car park. Nine Ø800 mm bored piles, 20 m long, stand in a 3 × 3 array at 2.4 m, three diameters apart. The ground is the clay profile of the Single Pile guide: 4 m of stiff clay over soft clay down to 10 m and stiff clay below that, with the water table at the ground surface. The cap carries 7,200 kN vertically and 900 kN horizontally, and it holds the pile heads against rotation.
Creating the calculation
Pick Pile Group Analysis in the Calculation Gallery and add it to your project with "Start Calculation". The input panel is on the left; the results are on the right. Analyse runs the axial and the lateral analysis together.

The input panel has seven sections. The badge on each says which half of the analysis reads it:
| Section | Data you define |
|---|---|
| Pile | Installation, length, section and material, EI and EA |
| Soil Profile | The layers, their p-y model and strength, the water table |
| Pile Array | Rows, piles per row, spacings, the loading direction, the efficiency rule and the block check |
| Loads on the Cap | The total vertical and lateral loads and the connection of the pile heads to the cap |
| Axial Analysis | Safety factors and load-transfer curves |
| Lateral Analysis | Static or cyclic loading and the deflection sweep |
| Solver | The number of nodes along the pile |
The pile and the soil profile
These two sections are the ones in the Single Pile macro, and the Single Pile guide explains them. The group analysis computes the single pile's capacity and each row's lateral response itself, from the same pile and the same layers.
A profile already entered in another pile calculation is taken with Take the profile from another calculation. The window lists the pile calculations you can open, grouped by project. The profile is copied, and the copy keeps no link to its source: editing either one later does not change the other.
In the example the last layer is then run on to 40 m. The block check reads the clay from the pile toe down to twice the block's width below it: here 20 m + 2 × 5.6 m = 31.2 m. A profile that ends sooner is averaged over the depth it has, and the run says so with a warning.
The pile array

Number of rows and Piles per row set the array; Row spacing and Spacing within a row set the distances between pile centres (left blank, the second takes the first). Loading direction says which way the lateral load pushes the array. It decides which piles stand in the shadow of which, and which spacing the p-multipliers are read with. The box under it gives the pile count, the block's plan dimensions B × Z measured to the outside of the perimeter piles, and the closest spacing as a multiple of the diameter.
The group capacity is the lesser of two mechanisms: the piles failing individually, reduced by an efficiency factor η, and the whole array failing as one block. The settings under Efficiency and block failure decide how they are computed:
| Setting | Effect |
|---|---|
| Your own efficiency factor (η) | Replaces the FHWA/AASHTO rule with your value; blank uses the rule, 1.0 means no reduction |
| Cap bearing on the ground | In clay, a cap in firm contact with the ground takes η = 1.0 (GEC 12 §7.2.2.2); off by default |
| Jetted or predrilled | Adds a warning that these methods loosen the soil; it changes no factor |
| Block failure check | Checks the array failing as one block (GEC 12 Eq. 7-36/7-37); keep it on |
In clay the rule gives η = 0.65 at a spacing of 2.5D and 1.0 at 6D, linear between, unless the clay along the block's faces is stronger than 2 ksf (about 96 kPa), in which case η = 1.0. A bored pile in sand follows a curve that reaches 1.0 at 4D, and a driven pile in sand takes 1.0.
Loads on the cap

The two totals are not treated alike. Total vertical load on the group is divided equally between the piles, and the line under it shows the load per pile. This holds for a rigid cap loaded at its centre; the macro does not distribute an eccentric load onto the piles. Total lateral load on the group goes to the analysis whole: it is shared out by the stiffness of each row, not equally.
Pile head — connection to the cap is Fixed when the cap holds the pile heads against rotation, as a rigid reinforced concrete cap does, and Pinned when it transfers no moment. Either way the cap imposes the same deflection on every pile.
Axial and lateral settings
The Axial Analysis section is the one in the Single Pile macro: the safety factors for the shaft and for the toe, the load-transfer curves and the depth with no side friction. The load direction is always compression, because group uplift follows a different model.
The Lateral Analysis section chooses static or cyclic p-y curves and sets the deflection sweep: Largest deflection swept (10% of the pile width when left blank) and Deflection steps. The analysis pushes the cap through that sweep, finds the deflection at which the rows together carry the applied lateral load, and solves each row there.
Reading the results
The band at the top gives the answer. The axial tile compares the load per pile with the allowable capacity per pile: 800.0 kN against 889.4 kN in the example, a ratio of 0.90. The lateral tile gives the common deflection and the largest shear and moment in any pile, here 0.89 mm, 141.6 kN and 208.5 kN·m. The third tile counts the warnings; in the example the one warning says that no shaft friction is counted over the top 1.52 m of a bored pile.
The Pile and Soil Section View cuts the array along the loading direction. It shows the layers the piles end in, the block and the base zone below the toe that the block check reads. The Plan layout shows the array from above, with each row's p-multiplier and its share of the lateral load.

The Group load-deflection curve is the whole cap's nonlinear lateral spring: the total lateral load against the common deflection. A frame model that needs the group as a support reads it from here, and it can be downloaded as CSV. The 3D view is for orientation; the cap it draws is not designed here.

Row distribution splits the lateral load between the rows. In the example the leading row takes 47.2% of it, against the 33.3% an equal split would give; the gap is the shadowing effect. The two charts below the bar follow each row's shear and moment per pile across the swept deflection (FHWA-HIF-18-031 Figure 7-7), and the table gives each row's p-multiplier, the shear per pile and per row, its share, and the largest moment with its depth. The fixed cap puts the largest moment at the pile head.
The working
Under the figures, the calculation is worked through step by step: each step with its formula, the same formula with the numbers substituted, and its result.

The axial half starts from the single pile: its ultimate capacity, 2,752 kN in the example, is computed inside the group analysis. The efficiency of 0.70 follows from the spacing of 3D, since the average strength along the block's faces, 81.19 kPa, is below 2 ksf. Nine piles at that efficiency give 1.734×10⁴ kN.

The block check sums the shear on the block's four faces and the bearing at its base. In the example the block can carry 8.221×10⁴ kN, so the individual piles govern. The allowable capacity applies the two safety factors to the shaft and the toe separately: 8,005 kN for the group, 889.4 kN per pile.

The lateral half reads each row's p-multiplier from AASHTO Table 7-1 (FHWA-HIF-18-031): 0.80, 0.40 and 0.30 at a spacing of 3B. Every row is then solved as a single pile with its own multiplier, at the deflection the cap imposes. The working ends with the simplified method the source allows, one averaged multiplier for every pile, and compares it with the row-by-row result: it gives a total within 2.4%, but it cannot say which row carries the largest moment.
Reading one row in Single Pile
The group analysis does not draw a row's moment diagram, its p-y curves or its depth to fixity. A group row is a single pile with a reduced p-y curve and the cap's deflection at its head, so Bring a row from a group analysis in the Single Pile macro brings it over, to be read with its own moment diagram, p-y curves and depth to fixity. The Single Pile guide shows how.
Generating the report
Generate Report produces a PDF that opens with the facts of the band at the top of the results, then gives the inputs, the axial and the lateral results, the working and the scope of the analysis. The button needs an up-to-date analysis: after an input changes, press Analyse again first.


Publishing and verification
Publish at the top of the page opens the Publishing & Verification window. Publish This Version freezes the calculation as it stands, its inputs and results together, into a copy that does not change, and gives that copy a verification link. Anyone with the link sees the copy read-only, without signing in. Editing the calculation afterwards leaves the copy as it was.

While the calculation is in its published state, the report carries a QR code that opens the link. The Single Pile guide describes the window in full.
What the analysis leaves out
The macro assumes one thing about the cap: every pile head moves by the same amount in the same direction. The cap's own lateral resistance, which can be a large part of a group's, is not counted; leaving it out is on the safe side. Eccentric vertical loads, cap moments, torsion and diagonal loading are outside the model, and group uplift is refused. Distributing a column's actions onto the piles is a separate problem the macro does not solve.