What Section Properties computes
Section Properties computes the geometric properties of a prismatic section of one material. Eight shapes are available: the rectangle and the circle, the pipe and the box, and the I / H, T, L and U profiles. Dimensions are entered in millimetres and the results are given in cm, cm², cm³ and cm⁴, with angles in degrees. Every result is written as an equation, so each number can be traced back to the dimensions it comes from. The tool is free with a StructuralMind account.
Pick Section Properties in the Calculation Gallery and add it to your project with "Start Calculation". The shape and its dimensions are at the top of the screen, the section drawing is on the left, and Geometric Properties is on the right with Generate Report below it. There is no Calculate button. Every change to a dimension updates the drawing and the results at once.

Choosing the section type
The shape thumbnail, marked Select Section Type, opens the shape gallery. The gallery groups the shapes as solid sections (Rectangle, Circle), hollow sections (Hollow circle (pipe), Box (hollow rectangle)) and profiles (I / H profile, T section, L angle, U channel). Picking a shape closes the window and fills in that shape's default dimensions.

Entering the dimensions
Each shape asks for its own dimensions. The drawing puts the flange of the T at the top, the legs of the L along the left and bottom edges and the web of the U on the left. The axes and centroid distances in the results refer to this orientation.
| Shape | Dimensions | Default (mm) |
|---|---|---|
| Rectangle | b width, h height | 200 × 400 |
| Circle | d diameter | 300 |
| Hollow circle (pipe) | D outer diameter, t wall thickness | 300, 12 |
| Box (hollow rectangle) | b and h outer width and height, t wall thickness | 200 × 300, 10 |
| I / H profile | h height, b flange width, tw web thickness, tf flange thickness | 400, 180, 10, 14 |
| T section | h height, b flange width, tw web thickness, tf flange thickness | 200, 200, 12, 16 |
| L angle | h vertical leg, b horizontal leg, t thickness | 150, 100, 12 |
| U channel | h height, b flange width, tw web thickness, tf flange thickness | 200, 75, 8.5, 11.5 |
A set of dimensions that cannot form the shape is not computed. The drawing is replaced by a warning that names the relation to restore: D greater than 2·t for the pipe, b and h greater than 2·t for the box, h greater than 2·tf and tw less than b for the I / H profile and the U channel, h greater than tf and tw not greater than b for the T section, and t less than both legs for the L angle.
Reading the results
The x axis is the horizontal axis through the centroid and the y axis the vertical one. Ix and Iy are taken about these two axes. Which rows appear depends on the symmetry of the section.
| Property | Symbol | When it appears |
|---|---|---|
| Area | A | Always |
| Centroid position | x̄, ȳ | Only on an axis the section is not symmetric about. x̄ is measured from the left edge, ȳ from the bottom edge |
| Second moment of area | Ix, Iy | Always |
| Elastic section modulus | Wx, Wy | One value per axis when the section is symmetric about it, otherwise one for each extreme fibre (Wx,top and Wx,bot, Wy,right and Wy,left) |
| Radius of gyration | ix, iy | Always, |
| Plastic section modulus | Zx, Zy | Always, about the axis that divides the area into two equal halves |
| Torsion constant | J | Always |
| Product of inertia and principal axes | Ixy, Imax, Imin, imin, α | Only when Ixy is not zero. Among these shapes that is the L angle |
For the I / H profile above, A = 87.6 cm², Ix = 23,071.63 cm⁴ and Wx = 1,153.58 cm³. The profile is symmetric about both axes, so its centroid sits at mid-height and mid-width, and each axis has a single elastic modulus.
Below the results a note states that the values are for sharp-cornered, idealised sections. For the open profiles and the box a second line says that J is approximate.
Unsymmetric sections
The L angle of 150 × 100 × 12 mm is symmetric about neither axis. Its centroid lies at x̄ = 2.45 cm from the left edge and ȳ = 4.95 cm from the bottom edge, and the drawing shows both centroidal axes through it.

Each axis therefore has two elastic moduli, one for each extreme fibre. About the x axis the top fibre gives Wx,top = 65.23 cm³ and the bottom fibre Wx,bot = 132.49 cm³. The smaller value belongs to the fibre farther from the centroid.
Because the product of inertia is not zero, the centroidal x and y axes are not principal axes. For this angle Ixy = −229.61 cm⁴, and the principal values are Imax = 756.97 cm⁴ and Imin = 135.36 cm⁴, with imin = 2.18 cm. The angle α = 23.81° is measured from the x axis to the axis of Imax, counterclockwise positive.

Torsion constant
The torsion constant J is computed by a different method for each group of shapes.
| Shape | Method |
|---|---|
| Rectangle | St. Venant's approximation for a solid rectangle with a ≥ b: |
| Circle, pipe | Exact closed form: and , d being the inner diameter of the pipe |
| Box | Bredt's formula for a thin-walled closed section: , with |
| I / H, T, L, U | Thin-walled open section: over the plates of the section (flanges, web or legs) |
The open-section sum leaves out the extra stiffness of the junctions, and Bredt's formula assumes a wall that is thin compared with the box. In both cases the result is approximate, and the note below the results says so.
Scope
- Idealised sections. Corners are sharp. Rolled steel profiles have root fillets and some have tapered flanges, so their catalogue values differ from the values computed here. For a rolled profile the manufacturer's catalogue gives the exact properties.
- Geometry only. The section has one material and no material property is used. Mass and self weight are not computed.
- Not computed. The warping constant and the shear centre are not part of the results.
Report
Generate Report produces a two-page PDF in the language of the interface. The first page lists the section type, its group and the dimensions, and shows the section drawing with its centroid and axes. The second page gives every property as an equation with its formula, followed by the same note as on the screen.

Publishing and verification
Publish at the top of the page opens the Publishing & Verification window. Publish This Version freezes the calculation as it is now and gives it a verification link that anyone can open. Editing the calculation afterwards leaves the published copy as it was. Publishing a state that is already published returns the same publication instead of a second one.
While the calculation is in its published state, the window marks it Current. Download PDF with QR then gives the report with a QR code that opens the verification page. Once an input changes, the report no longer matches the publication and the QR is left out. Publish again to restore it.

Using a section in other calculations
The same shapes and the same calculation are used in two other places.
- Beam Analysis. The ruler icon in the beam's I field, "Compute from section", opens a window with the shape gallery and the dimension fields. Under Bending axis, Strong (Ix) takes the second moment of area about the x axis and Weak (Iy) about the y axis, and Use this section writes the value into the beam. The beam's report then carries a page with the section's properties.
- Single Pile and Pile Group. The Section and Material window computes the area and the second moment of area of the pile section in the same way, and with the material's modulus of elasticity gives EI and EA.