What's new in StructuralMind: November 2026
Floor and stair vibration is now calculated straight from a structural model built in the browser, and the model can be edited by typing a command.

On this page
- Floor Vibration Analysis
- Three guides
- Each area against its own limit
- Stairs, machinery and partitions
- Report, publishing and verification
- Model Editor
- Build the model in the browser, as a team
- DXF underlay
- The analysis model builds itself
- Model audit
- Shell structures, stairs and ramps
- Loads, the section plane and storeys
- AI Assistant
- MindFEM
- Trial and plans
On most projects, a floor vibration check is a job of its own. The floor is modelled again in an analysis program, the results are assessed separately against the guide's method, and every change to the plan means doing it all again.
Floor Vibration Analysis, the Model Editor and the AI Assistant, released this month, share one aim: to remove that repetition. The structural model is built once, edited with the AI assistant and used directly in the vibration analysis. The analysis runs on MindFEM, StructuralMind's own finite element engine.
Floor Vibration Analysis
Floor Vibration Analysis builds a finite element model from the storeys you set up in the Model Editor and calculates the vibration that walking, running, rhythmic activity and rotating machinery cause in floors and stairs. Because the model comes from the Model Editor's storeys, the vibration check can be made early in the design, without building a separate model. When the plan changes, the analysis is run again from the same model.

Three guides
Each calculation follows SCI P354, CCIP-016 or AISC DG11. The guide chosen sets the whole method, from the modelling rules to the quantity the result is given in. The same floor can be solved under different guides in separate calculations and the results compared.
Each area against its own limit
One floor can hold offices, meeting rooms and laboratories, each with its own sensitivity to vibration. The whole floor and every area you draw are assessed separately. Each area is compared with the limit for its room type, and its least favourable point is reported.

Stairs, machinery and partitions
Concrete and steel stairs are solved with their own models, and their walking response is assessed with the SCI P354 or AISC DG11 method. The vibration rotating machinery causes in a floor can be calculated too. Partitions enter the model as mass where they stand, and the stiffness of permanent full-height partitions can be included as an option.

Report, publishing and verification
A PDF report with the calculation steps can be produced, and the calculation can be published as an immutable copy and shared with a verification link. The calculation has been tested against the worked examples of the three guides. The floor response has been compared with an ETABS time-history solution, and the stair response with a SAP2000 solution. The results are on the verification page.
Model Editor
The Model Editor is where the structural model behind the vibration analysis is built. Once the storeys are defined, axes, columns, beams, walls, slabs, partitions, braces and equipment are drawn on the floor plan. A member's dimensions are edited in the properties panel after it is drawn, and the same model is reviewed in 3D.
Build the model in the browser, as a team
With desktop programs, the model file passes from hand to hand within a team, and which copy is the latest can get confused. The Model Editor runs in the browser, so there is nothing to install, and the model is stored with its project. While one person edits the model, the rest of the team sees it read-only, so everyone sees its latest state.
DXF underlay
The architectural plan is often redrawn in the structural model. In the Model Editor, the architect's DXF file is placed as an underlay instead. Its lines can be turned into axes, closed shapes into columns and long rectangles into walls, so the model is built on the architectural plan itself.

The analysis model builds itself
In a finite element program, nodes, member connections and supports are often set up by hand. In the Model Editor, only the members are drawn. Where a beam meets a column or another beam, a node is created. Joints are rigid, and the engineer sets the ends that need a release.
The resulting model is shown in the idealized view with member axes, shell surfaces, supports and loads, and the view's status bar gives the number of nodes and diaphragms. The finite element mesh is generated during the analysis. Supports, loads and member connections can therefore be checked before the analysis is run.

Model audit
A modelling error is often noticed only when an analysis result looks wrong. The model audit lists what would stop the analysis or change its result before the analysis is run, and shows the member involved: a beam joined to nothing, a member standing on nothing, a member drawn twice or self weight counted twice.
Shell structures, stairs and ramps
Curved and folded surfaces such as domes, vaults and stairs often need a hand-built mesh in a finite element program. In the Model Editor, besides flat slabs, vaults, domes, folded plates, pendentives and sail vaults are defined by their dimensions, and their mesh is generated during the analysis.

Stairs are not picked from a list of types; their flights and landings are drawn on the floor plan. Stairs with winders, curved flights, a landing that splits into two flights, spiral stairs and ramps can be modelled in concrete or steel. A stair enters the model with its real geometry, and its vibration is solved with its own model.

Loads, the section plane and storeys
Area, line and point loads are assigned to load cases and shown to scale in 3D. A section plane and per-type transparency let you look inside the model. Selected members are copied to several storeys in one step, so similar storeys are built once instead of being drawn one by one.


A static or seismic analysis of the whole building cannot be run from the Model Editor yet. Today the model is used by Floor Vibration Analysis.
AI Assistant
The AI assistant adds axes, storeys, members and loads to the Model Editor from the command you type, and changes or deletes what is already there. Commands can be written in any language, and the assistant replies in the language of the command.
Edits that touch many members at once, such as copying a storey's columns to the storeys above or changing a section on every storey, take one command.
Every change the assistant would make is shown as a preview. Members to be added, changed and deleted are marked in their own colours and counted. Choosing Apply writes the change to the model, and one undo takes it back, so every change the assistant makes passes through the engineer's hands.

The assistant summarises the model, lists its members, runs a quantity takeoff and runs the model audit. It does not run analyses or calculations. Its answers to structural engineering questions are opinions for the engineer to judge.
MindFEM
MindFEM's features, verification examples and comparisons with other programs are on the MindFEM page.
Trial and plans
Floor Vibration Analysis and the Model Editor are on the paid plans and can be tried free for 30 days, with no credit card. The AI assistant is included only in paid plans and is not offered during the trial.
We will keep developing these features with our users' feedback. You can send yours to support@structuralmind.com.
Get new posts by email
Engineering writing and product notes, straight to your inbox.
Unsubscribe at any time.Privacy Policy